The SCB10 series Resin Insulated Dry-type Transformer independently developed by Kexun Electric in China Factory has the characteristics of flame retardancy, fire prevention, explosion prevention, maintenance-free, pollution-free and small size, and can be directly installed in the load center. Equipped with intelligent temperature controller, it has the functions of fault alarm, overtemperature alarm, overtemperature trip and black brake.
Model:SCB10
Brand:KEXR

● Components of SCB10 type Resin Insulated Dry-type Transformer

◆Core of Resin Insulated Dry-type Transformer

The iron core is made of imported high-quality cold-rolled silicon steel sheets, with a fully inclined joint structure. The core column is tied with F-grade non-woven adhesive tape, and the surface of the iron core is encapsulated with epoxy resin to reduce no-load-loss, no-load current, and iron core noise, The clamps and fasteners have undergone special surface treatment to further improve the appearance quality of the product.

◆Low voltage winding

The Resin Insulated Dry-type Transformer ‘s low-voltage winding adopts a foil structure, which solves the problem of axial helix angle when using wire winding, making the turns more balanced. At the same time, the coil adopts an axial cooling air duct, enhancing the heat dissipation ability. TDMD epoxy resin prepreg is used between the winding layers, and the whole is cured and formed.

◆High voltage winding The SCB10 series Resin Insulated Dry-type Transformer

The high-voltage winding is vacuum cast with epoxy resin with fillers, greatly reducing the local discharge and improving the electrical strength of the coil. The inner and outer walls of the winding are filed with glass fiber mesh plates, enhancing the mechanical strength of the coil and improving the product's ability to resist sudden short circuits, The coll never cracks.

◆ Manufacturing process

The coil of SCB10 type Resin Insulated Dry-type Transformer is wound on a high-precision winding machine, and the low-voltage winding adopts a foil winding structure. When the transformer capacity is large, there is a ventilation duct. After the winding is completed, vacuum drying is carried out, and the entire pouring and curing process is completely operated according to the process requirements, All processes need to be strictly monitored and adjusted according to the situation. The precision manufacturing process of pouring ensures that the coil has no bubbles or voids, resulting in high-quality operation of the transformer.

◆Temperature control system and air cooling system

The cross flow top blowing cooling fan is adopted, which has the characteristics of low noise, high air pressure, and beautiful appearance, enhancing the overload capacity of the SCB10 type Resin Insulated Dry-type Transformer., The temperature control adopts an intelligent temperature controller, which improves the safety and reliability of transformer operation.

◆Protect the casing and output busbar

The protective shell provides further safety protection for the transformer, with protection levels of iP20, lP23, etc, The shell material includes cold-rolled steel plate, stainless steel plate, etc, for users to choose from, Low voltage outgoing lines use standard busbars, both side and top outgoing lines can be used, and special outgoing methods can also be designed for users.

◆Transformer outgoing line method

Conventional outgoing lines, standard enclosed busbars, and standard side outgoing lines can be manufactured according to different interface forms, and special outgoing methods can also be designed according to user requirements.

 

◆ Related standards & parameters

GBT10228-2015.GB1094.11-2007

JBT10088-2004,GB4208-1993

Rated high voltage: 10 (11,10.5,6.6,6.3,6) KV

Rated low voltage: 0.4KV

Connection group: Dyn11 or YynO

High voltage tap range: + 5 or + 2X2.5%

Insulation level: Ll75AC35/LI0AC5

Frequency: 50Hz

 

◆ Appearance and installation dimension of the SCB10 type Resin Insulated Dry-type Transformer

Resin Insulated Dry Type TransformerResin Insulated Dry Type Transformer

 

◆Technical parameters of 10KV SCB10 type Resin Insulated Dry-type Transformer

Rated

capacity

(kVA)

Voltage combination and tap range (kV)

Group

 

 

 

 

Number

No

Load

loss

Temperature of different insulation Systems Load loss below (kW)

No

 

Load

 

Current

(%)

Short

circuit

impe

dance

(%)

 

Weight

 

 

 

 

(kg)

L

*

W

*

H

mm

Installation

 

Size

(mm)

L

*

W

*

H

(With

Shell)

HV

 

 

(KV)

High voltage division pressure Range of acceptance

LV

 

 

(KV)

120℃

30

 

 

 

 

6

6.3

6.6

10

10.5

11

 

 

±2.5

±5

 

 

 

 

 

 

 

 

0.4

 

 

Dyn11

 

Yyn0

0.19

0.71

2

 

 

 

 

 

 

4

270

590*500*640

400/400

1000x900x1050

50

0.27

1

2

360

620x550x670

400/400

1000x900x1050

80

0.37

1.38

1.5

510

680x580x710

400/450

1050x950x1100

100

0.4

1.57

1.5

570

720x600x720

400/450

1100x950x1150

125

0.47

1.85

1.3

600

860x650x850

550/550

1250x1000x1300

160

 

 

 

 

 

±2*2.5

 

±5

0.54

2.13

1.3

730

900x710x890

550/550

1300x1050x1350

200

0.62

2.53

1.1

850

940x750x980

550/660

1300x1100x1500

250

0.72

2.76

1.1

980

960x770x1030

660/660

1300x1100x1550

315

0.88

3.47

1

1130

1020x790x1060

660/660

1400x1150x1550

400

0.98

3.99

1

1330

1060x880x1100

660/820

1450x1200x1600

500

1.16

4.88

1

1480

1080x900x1160

660/820

1450x1200x1700

630

1.3

5.96

0.85

 

 

 

 

6

1580

1200x920x1150

820/820

1550x1200x1700

800

1.52

6.96

0.85

1910

1260x920x1260

820/820

1600x1200x1800

1000

1.77

8.13

0.85

2260

1320x940x1300

820/820

1700x1250x1800

1250

2.09

9.69

0.85

2660

1380x950x1380

820/820

1750x1250x1900

1600

2.45

11.7

0.85

3180

460x1120x1490

1070/1070

1850x1400x2000

2000

3.05

14.4

0.7

3600

490x1120x1620

1070/1070

1900x1450x2200

2500

3.6

17.1

0.7

4220

520x1120x1760

1070/1070

1950x1500x2200

3150

5.14

22.5

0.6

5000

600x1120x1860

1070/1070

2000x1550x2300

4000

5.96

27

0.6

6300

680x1120x2150

1070/1070

2100x1600x2600

 

 

Hot Tags: Resin Insulated Dry-type Transformer, Resin Insulated Transformer, Dry-type Transformer Supplier